Dachdurchführung mit vs. ohne MC4-Ausbau – Der Vergleich für Installateure - NEXCAPE

Roof Grommet with vs. without MC4 Connector Extension – A Comparison for Installers

Which Roof Vent for Which Tile? Guide for Commercial Customers Reading Roof Grommet with vs. without MC4 Connector Extension – A Comparison for Installers 4 minutes Next Laying PV cables: 5 mistakes homeowners should avoid

The dilemma for every PV installer: You have to run solar cables through a roof. But the MC4 connectors are too large for conventional openings. The classic solution? Disassemble MC4 connectors – time-consuming and prone to errors. But there is a better alternative.

The Problem: Why MC4 Disassembly Is Necessary at All

Solar modules are delivered with MC4 connectors (diameter approx. 13–15 mm). However, conventional roof penetrations are only designed for 8–10 mm. The result:

  • MC4 connectors must be manually disassembled and reassembled
  • Time expenditure per module: 15–25 minutes
  • Risks: Damaged contacts, incorrect connections, safety problems

For a typical 8-module system, this means: 2.5–3.5 hours just for connector assembly – and 162–262 Euros in additional costs.

The Alternative: NEXCAPE® Roof Penetration Without MC4 Disassembly

The NEXCAPE® Roof Penetration has a wider channel opening, through which the complete MC4 connector fits – without disassembling it.

  • Wider channel opening: MC4 connectors fit through with room to move
  • 100% TPU: UV-resistant, long-term stable for decades
  • Abrasion protection: Protects cables from wear due to tile movements
  • Made in Germany: Highest quality standards in development and manufacturing
  • No tools required: The connector is simply pushed through

Comparison Table: With vs. Without MC4 Disassembly

Criterion With MC4 Disassembly (classic) Without MC4 Disassembly (NEXCAPE®)
Time per Module 20–25 Min. 2–3 Min.
Total Time (8 Modules) 2.5–3.5 Hours 16–24 Min.
Tools Required Yes: Connector tool No: Entirely manual
Risk of Error High: Contact damage Minimal: No manipulation
Module Manufacturer Warranty Risk: Manipulated connectors No Risk: Connectors untouched
Long-term Durability 10–15 Years 25+ Years (Made in Germany)

Cost Calculation: How You Save with Every Installation

With MC4 Disassembly (classic): 8 modules × 22 min = 176 min = 2.93h → 205 Euros labor costs for connectors only

Without MC4 Disassembly (NEXCAPE®): 8 modules × 2.5 min = 20 min = 0.33h → 23 Euros labor costs

Your savings per installation: 182 Euros. With 10 installations per month: 1,820 Euros. With 100 per year: 18,200 Euros.

Installation: Step-by-Step

Classic (with MC4 Disassembly) – 20-25 Min/Module

  1. Disassemble MC4 connectors with tools
  2. Thread individual cables through the penetration
  3. Reconnect below the penetration
  4. Check fit, re-adjust if necessary

NEXCAPE® (without MC4 Disassembly) – 2-3 Min/Module

  1. Guide MC4 connector with full cable through the penetration
  2. Check fit – done

Frequently Asked Questions

Isn't a larger opening less watertight?
No. The NEXCAPE® penetration uses special UV-resistant TPU that adapts to the connector and provides reliable abrasion protection.

Does this work on tiled roofs?
Yes, the NEXCAPE® penetration was specially developed for tiled roofs – Frankfurter Pfanne, Biberschwanz, Doppelmuldenfalzziegel and more.

How long does the penetration last?
High-quality penetrations made of UV-resistant 100% TPU last 25+ years.

Conclusion: Why "without MC4 disassembly" is becoming the new standard

  • 90% less time per module
  • 180+ Euros savings per installation
  • No sources of error, no liability risks
  • Connectors remain unchanged, module warranty remains valid
  • Made in Germany, 25+ years of reliability

For B2B commercial customers, we offer package solutions from 20 to 1,000 units.

Contact: support@nexcape.de | Tel: 07054 927999 | Mon–Fri 8:00–17:00

Discover NEXCAPE® Roof Penetrations now on dachdurchfuehrung24.com


From our manufactory: PV Roof Penetrations

Matching Product: View PV Roof Penetration without MC4 Disassembly


Matching PV Roof Penetrations from our manufactory: All PV Roof Penetrations · DIY version without MC4 disassembly · 125 mm for Frankfurter Pfanne · 150 mm for almost all roof tiles